Schalk Isolating relay
7 pieces in stock at supplier
Product details
Schalk Active Isolation Relay ATR U2
Manufacturer: Schalk
Designation: Active Isolation Relay 1W, 230V AC/24V DC PELV
Type: ATR U2
Electrical connection type: Screw connection
With removable terminals: no
Rated current: 10 A
Rated control supply voltage Us at AC 50 Hz: 207..253 V
Rated control supply voltage Us at AC 60 Hz: 207..253 V
Rated control supply voltage Us at DC: 24 V
Voltage type for actuation: DC
Switching behavior of the actuator: monostable
Number of contacts as changeover: 1
With forced-guided contacts: yes
Type of switching contact: Single contact
With LED indicator: yes
Width: 43 mm
Height: 43 mm
Depth: 18.5 mm
The ATR U2 allows for the simplest control of mains voltage consumers through low voltage contacts. A power supply for actuating the relay coil is not required, as the ATR U2 internally generates the necessary control voltage (24V DC PELV). In conjunction with the magnetic contact MKW 1, it is thus possible to implement a supply air monitoring system, often required for enclosed spaces, when operating exhaust fans with minimal effort. However, due to the 10A changeover contact, the ATR U2 is also very versatile for other applications. Dimensions: 43x43x18.5 mm, 230V AC - 1W 10A.
input voltage | 24 V |
Electric current output | 10 A |
Item number | 20348633 |
Manufacturer | Schalk |
Category | Relays |
Manufacturer no. | ATRU29 |
Release date | 30-3-2022 |
External links |
input voltage | 24 V |
Electric current output | 10 A |
Switching function | Changer |
Country of origin | Germany |
CO₂ emissions | 29,26 kg |
Climate contribution | EUR 0,75 |
Width | 43 mm |
Height | 43 mm |
Product Safety |
30-day right of return
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Relays» category have a defect within the first 24 months?
Source: Galaxus- 7.Eltako0,3 %
- 8.Hager0,6 %
- 8.Schalk0,6 %
- 10.Aqara0,8 %
- 11.Shelly1,1 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- SchalkNot enough data
- 1.Shelly1 day
- ABBNot enough data
- AqaraNot enough data
- EatonNot enough data
Return rate
How often is a product of this brand in the «Relays» category returned?
Source: Galaxus- 1.Phoenix Contact0 %
- 3.Tru Components0,5 %
- 4.Schalk0,8 %
- 5.Hager1,9 %
- 6.Shelly2,2 %