Schneider Electric SE 18825 LS switch, C-Char, 32A, 4p
Product details
Acti 9 NG125L circuit breaker, 50 kA (IEC/EN 60947-2). 4-pole, rated current 32 A, C-characteristic, operating voltage (Ue) 380-415 V AC, insulation voltage (Ui) 690 V AC. Protection of the circuit against short-circuit currents. Protection of the circuit against overload currents. The tripping is indicated by the middle position of the switching lever and by a red mechanical display on the front of the device. Test button to check the tripping mechanism. Top or bottom feed. Jump switching for low-wear contact operation. Tripping unit technology - thermomagnetic. Additional snap-on auxiliary modules (optional) - display of switching position, fault tripping, operating current tripping, undervoltage tripping, overvoltage tripping. The NG125L circuit breaker complies with the following standards - IEC/EN 60947-2.
Circuit breaker type | Circuit breaker, Miniature circuit breaker |
Mounting type | Built-in installation |
number of poles | 4 |
Length | 81 mm |
Width | 108 mm |
Item number | 32117394 |
Manufacturer | Schneider Electric |
Category | Residual-current device |
Manufacturer no. | 18825 |
Release date | 16-11-2022 |
Circuit breaker type | Circuit breaker, Miniature circuit breaker |
Mounting type | Built-in installation |
number of poles | 4 |
Tripping characteristic | C |
Rated current | 32 A |
Rated voltage | 400 V |
voltage type | AC, DC |
Rated insulation voltage Ui | 690 V |
Protection type (IP code) | IP20 |
Country of origin | France |
Manufacturer commitment | RE100, SBTi |
CO₂ emissions | 29,26 kg |
Climate contribution | EUR 0,75 |
Items per sales unit | 1 pcs. |
Length | 81 mm |
Width | 108 mm |
Height | 103 mm |
Product Safety |
30-day right of return
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Galaxus- 1.Siemens0 %
- 4.ABB0,1 %
- 4.Schneider Electric0,1 %
- 6.Hager0,2 %
- 7.Steffen0,4 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
- Max HauriNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus- 2.Eaton0,7 %
- 2.Max Hauri0,7 %
- 4.Schneider Electric1,4 %
- 5.ABB2 %
- 6.Siemens3,6 %